Alexandrite laser manual
Alexandrite laser manual – optical alexandrite beauty device adopts Japan‑imported Mitsubishi optical fiber transmission, supports dual‑wavelength 755nm &1064nm output, built‑in water‑cooling & compressor refrigeration cooling system, stable energy output, covering multi‑skin‑type hair‑removal demand
Alexandrite laser 755nm and ND yag laser 1064nm are options on same machine. Using single way or dual-way output will decide machine have one single wavelength to two wavelength options.
Dual‑wavelength Option
755nm Alexandrite laser +1064nm Nd:YAG laser, compatible with skin type I‑VI, effective for both light and dark hair, acting on superficial and deep hair follicles.
Japan Mitsubishi Optical Fiber
Equipped with Japan‑imported Mitsubishi optical fiber (φ1.0mm,length:220mm), low light loss & even beam. Adjustable spot size from 6‑18mm, greatly improve working efficiency for large‑area treatment.
Dual Cooling System
Water‑cooling plus compressor refrigeration. Handpiece skin cooling temperature:‑5~5℃, reduce thermal injury, erythema and burn risk for better patient comfort. 15L water tank, only distilled or purified water is allowed. Tap /mineral water is forbidden.
Adjustable Clinical Parameters
Energy:1‑100J/cm², Pulse Duration:10‑100ms, Frequency:0.5/1/2Hz. 10‑inch true‑color touch screen, visual parameter setting, preset reference parameters for different skin tones, user‑friendly for operators.
Complete Safety Protection
Standard accessories include operator safety goggles & patient eye‑shields. Built‑in water‑flow alarm, water‑temperature alarm and emergency‑stop switch. High‑voltage components inside, disassembly only allowed for authorized technicians.
| Item | Parameter |
|---|---|
| Display | 10‑inch True‑color Touch Screen |
| Laser Wavelength | 755nm Alexandrite /1064nm Nd:YAG |
| Frequency | 0.5Hz /1Hz /2Hz |
| Spot Size | 6‑18mm Adjustable |
| Pulse Duration | 10‑100ms |
| Max Energy | 100J/cm² |
| Aiming Beam | 650nm Red aiming beam |
| Fiber | Mitsubishi Japan,φ1.0mm L=220mm |
| Cooling | Water‑cooling + Compressor refrigeration |
| Power Supply | AC110V/220V,3500W,50‑60Hz |
| Water Tank | 15L |
| Working Ambient | temperature 10‑40℃; humidity≤80% RH |
| Machine Dimension | 42×83.4×74cm |
Alexlandrite laser operation Notes
Before Power‑on
- Confirm normal water circulation before startup. Fill distilled/purified water until water flows out from overflow port. Never use tap water to avoid scale damage.
- Keep water‑injection & overflow port open; keep drainage cap closed all time. Blocking overflow port will burn the machine.
- All operators must wear laser safety goggles, patients wear eye shields. Remove mirror‑like reflective objects in treatment room.
Clinical Procedure
- Clean treatment skin, leave short hair root;
- Set parameters per skin type, perform spot test first, observe skin reaction before formal treatment;
- Fire laser by foot pedal; keep patient under observation for 20 mins post‑treatment;
- Shutdown steps: return to wavelength selection screen, turn key counter‑clockwise to power‑off, disconnect power cable.
Maintenance
- Minimum cooling‑water replacement cycle: 1 month.
- Weekly visual check for cables & emergency‑stop switch. Clean handpiece lens after every treatment with ≥98% alcohol and lint‑free soft cloth.
- Wait 10 minutes after power‑off before any maintenance. High‑voltage inside, back‑cover opening forbidden for non‑authorized staff.
- Annual professional calibration & power‑meter inspection by authorized technicians.
Troubleshooting Tips
Only simple faults can be checked by users. For water‑flow alarm, no laser output or system error, please contact our technical support, do NOT open machine housing.
| Fault | Quick Check |
|---|---|
| Water flow alarm | Check whether the water level is filled to capacity and ensure there are no air bubbles in the water lines. |
| Water temperature alarm | Check whether the ambient temperature is too high; check the condition of the cooling water. |
| Cannot power‑on | Check the status of the power cord, residual current circuit breaker (RCCB), and fuses. |
| No laser output with pedal | Ensure the device is in Standby mode and check the footswitch connector. |
Application Scenarios
Professional medical‑beauty clinics, high‑end beauty salons & skin care centers, for laser hair removal for various skin phototypes.
Guangzhou Cosnext Technology Co.;Ltd